KONAN ELECTRIC CO.,LTD.
_ HOME PROFILE CONTACT US PRODUCTS
HOME > PRODUCTS > Pneumatic Solenoid Valves > Intrinsic Safety Solenoid Valves
PRODUCTS
Solenoid Valve for Various Fluid
Pneumatic Solenoid Valves
Pneumatic Cylinders
Pneumatic Rotary Actuators
Pneumatic Controls
Sanitary Valves
Packing System
Intrinsic Safety Solenoid Valves

Intrinsic safety valves can be used for applications that require similar explosion class/ignition degree to d2G4 or Exd II BT5 type (explosion-proof enclosure construction). Without need for expensive connection tools and complex installation work that are inevitable for explosion-proof enclosure types, the intrinsic safety valves achieve highly reliable explosion-proof performance.

 Explosion barrier  SAF3-5 , MTL728+

Intrinsic safety explosion barrier is an explosion-proof device with single channel, shunt-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy transmission in order to prevent ignition in explosive atmosphere.

1.Applicable to Zone 0.

2.When serially connected to a transmission circuit, the barrier protects

   the circuit and components in hazardous area from being affected by 

   a serious accident in the non-hazardous area.

3.Despite in the hazardous location, conventional wiring is available.

4.Intrinsical proof of operational signal is figured out easily and at lower

   cost.
5.As SAF3-5 safety barrier has protection circuit, it will be not broken

   if you wired in the wrong polarity.
6.SAF3-5 safety barrier employ crimping terminal wiring method.

Model code SAF3-5 MTL728+
Explosion-proof construction Intrinsic safety construction(ExiaⅡB) Intrinsic safety construction(i2G4) 
Rated voltage DC24V±5% -
Max. working voltage - DC25.5V
Max. allowable voltage - DC26.6V
Safety retention voltage AC/DC 250V
Rating of a fuse 50mA
Ambient temp. -20~60℃ -10~60℃
Basic circuit figure
Operating condition

1.Place the valve in non-hazardous area.

2. Parts and connections cannot be changed.

3. Use with specified solenoid valves.

 4. Allowable inductance for external connection: 10mH / Capacitance: 0.5 μF

 4. Allowable inductance for external connection: 1mH / Capacitance: 0.05 μF

 Explosion barrier  SAF100-5

Intrinsic safety explosion barrier is an explosion-proof device with single channel, Zener-diode DC circuit that enables interactive electric signaling without short circuit while controlling energy transmission in order to prevent ignition in explosive atmosphere.

1.Applicable to Zone 0.

2.A-class ground is not necessary since the input and output are insulated

   each other.

3.When serially connected to a transmission circuit, the barrier protects

   the circuit and components in hazardous area from being affected by 

   a serious accident in the non-hazardous area.

4.Despite in the hazardous location, conventional wiring is available.

5.Intrinsical proof of operational signal is figured out easily and at lower

   cost.

6.SAF100-5 safety barrier employ crimping terminal wiring method.

7.As SAF100-5 safety barrier has protection circuit, it will be not broken

   if you wired in the wrong polarity.
8.LED indicates the condition of the input and output.

Model code SAF100-5
Explosion-proof construction Intrinsic safety construction(ExiaⅡC)
Rated voltage DC24V±10%
Maximum voltage of a intrinsic safety circuit DC29.4V
Max. allowable voltage DC25.95V
Maximum current of a intrinsic safety circuit 93.8mA
Electric power of a intrinsic safety circuit 0.689W
Ambient temp. -20~50℃
Basic circuit figure

Does not need A-class ground.

Operating condition

 1.Place the valve in non-hazardous area.

 2.Perform single grounding using type A ground.

 3. Parts and connections cannot be changed.

 4. Use with specified solenoid valves.

 5. Allowable inductance for external 

    connection: 2mH / Capacitance: 0.05 μF

 454 series 5-port solenoid valves (spool valve)
  Return Hold
Kind of barrier to combine i2G4 MTL728+ 454S202C-Yi 454S203C-Yi 454S403C-Yi 454S404C-Yi 454D202C-Yi 454D203C-Yi 454D403C-Yi 454D404C-Yi
ExiaⅡBT5 SAF3-5 454S202M-Yi 454S203M-Yi 454S403M-Yi 454S404M-Yi 454D202M-Yi 454D203M-Yi 454D403M-Yi 454D404M-Yi
In the case of other explosion-proof barriers and combination *1
Structure of the main valve

Pilot spool type 

Port size Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2
Effective area of valve 22mm2 40mm2 22mm2 40mm2
Working pressure 0.2~0.7MPa
Ambient temp. -5~50℃
Explosion-proof standard Intrinsic safety construction
Operating condition

1. Use with specified safety barrier.

   For i2G4 explosion-proof valves, use them with MTL728+ safety barrier. 

   For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the

   conditions described below (note *1).

2. Parts and connections cannot be changed.

3. Use 1 explosion-proof barrier for each solenoid valve.

 414/416 series 5-port solenoid valves (Spool valve / Ceramic slide valve)
  Return
Kind of barrier to combine i2G4 MTL728+ 414S302C-Yi 414S303C-Yi 414S603C-Yi 414S604C-Yi 416S302C-Yi 416S303C-Yi 416S603C-Yi 416S604C-Yi
ExiaⅡBT5 SAF3-5 414S302M-Yi 414S303M-Yi 414S603M-Yi 414S604M-Yi 416S302M-Yi 416S303M-Yi 416S603M-Yi 416S604M-Yi
In the case of other explosion-proof barriers and combination *1
Structure of the main valve Pilot spool type Pilot ceramic slide type
Port size Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2
Effective area of valve 25mm2 30mm2 51mm2 60mm2 24mm2 28mm2 51mm2 60mm2
Working pressure 0.2~0.7MPa 0.12~0.7MPa
Ambient temp. -5~50℃ -10~60℃
Explosion-proof standard Intrinsic safety construction

Operating condition

1. Use with specified safety barrier.

   For i2G4 explosion-proof valves, use them with MTL728+ safety barrier. 

   For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the

   conditions described below (note *1).

2. Parts and connections cannot be changed.

3. Use 1 explosion-proof barrier for each solenoid valve.

 414/416 series 5-port solenoid valves (Terminal block ZA) (Spool valve/Ceramic slide valve)
  Return
Kind of barrier to combine ExiaⅡBT5 SAF3-5 414S302M-YAi 414S303M-YAi 414S603M-YAi 414S604M-YAi 416S302M-YAi 416S303M-YAi 416S603M-YAi 416S604M-YAi
In the case of other explosion-proof barriers and combination *1
Structure of the main valve Pilot spool type Pilot ceramic slide type
Port size Rc1/4 Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/2
Effective area of valve 25mm2 30mm2 51mm2 60mm2 24mm2 28mm2 51mm2 60mm2
Working pressure 0.2~0.7MPa 0.12~0.7MPa
Ambient temp. -5~50℃ -10~60℃
Explosion-proof standard Intrinsic safety construction
Operating condition

 1. Use with specified safety barrier.

   For Exia II BT5 explosion-proof valves, use them with the safety barrier SAF3-5 or that meets the

   conditions described below (note *1).

2. Parts and connections cannot be changed.

3. Use 1 explosion-proof barrier for each solenoid valve.

note *1

In the case of other barriers and combination

Konan 454, 414, 416 series intrinsic safety solenoid valves have passed equipment qualification tests for intrinsic safety solenoid valve.

The valves can be used in combination with the safety barrier that meets the following conditions. (The valves can be used with insulation barrier that does not need type A ground.)

The barrier used in combination with the valves should be the one that has passed equipment qualification tests for a barrier and that meets the following conditions.

Safety retention voltage Maximum voltage of a intrinsic safety circuit Less than 29.4V
Maximum current of a intrinsic safety circuit Less than 93.8mA
Electric power of a intrinsic safety circuit Less than 0.689W

Performance classification / Group

Performance classification ia
Group ⅡB or ⅡC

Allowable inductance (Lo) and capacitance (Co) for an intrinsic safety circuit and relationship between inductance (Lo) and capacitance (Cw) for external connections to the intrinsic safety circuit

Allowable inductance of a intrinsic safety circuit:Lo≧Li+Lw(mH)

Allowable capacitance of a intrinsic safety circuit:Co≧Ci+Cw(μF)

 
 
 
KONAN LOGO Copyright(C)2010 KONAN ELECTRIC CO.,LTD.
 
     
JAPANESE chinese