Powerful Solenoid Valves for Heavy-Duty Applications for Pneumatic control

Powerful Solenoid Valves for Heavy-Duty Applications for Pneumatic control
konan's Powerful Solenoid Valve for Heavy-duty Applications has proven excellent performance as a key component for pneumatic automation systems in various factories and plants.
With sophisticated shape and function established through abundant experiences, this valve is continuing to provide powerful and highly reliable performance under harsh
environment and conditions.
●Powerful solenoid.
●Contamination-resistant pilot valve
●Reliable control mechanism

MVW1(R) 3-Port Solenoid Valves

  • MVW1(R) 3-Port Solenoid Valves
■MVW1(Normally closed)MVW1R(Normally open)
■Poppet valve system, Direct acting type
■Direct piping type
■Port size:Rc1/4 , Rc1/8
Model code Normally closed MVW1
Normally open MVW1R
Port size Rc1/4 , Rc3/8
Operating pressure 0~0.7MPa
Fluid temperature -20~60℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Ambient temperature -20~50℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Effective sectional area 3.8mm2
Rated voltage AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V,110V,200V,220V
Response time AC ≦ 0.02 s
DC ≦ 0.026s
Max. operating frequency 1 cycle /s
Internal leakage JIS B8374 standard value
Installation position Free
Mass 1.2kg
●Use the valve with lubricator.
●Refer to catalog for details.

MVW71(R),MVW7(R) 3-Port Solenoid Valves

  • MVW71(R),MVW7(R) 3-Port Solenoid Valves
■MVW71,MVW7(Normally closed)MVW71R,MVW7R(Normally open)
■Poppet valve system, Pilot-acting type
■Direct piping type
■Port size:Rc3/8 , Rc1/2 , Rc3/4 , Rc1
Model code Normally closed MVW71 MVW7
Normally open MVW71R MVW7R
Port size Rc3/8 Rc1/2 Rc3/4 RC 1
Operating pressure MVW71,MVW7 0.12~0.7MPa
MVW71R,MVW7R 0.2~0.7MPa
Fluid temperature -20~60℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Ambient temperature -20~50℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Effective sectional area 65mm2 75mm2 160mm2 190mm2
Rated voltage AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V,110V,200V,220V
Response time AC ≦ 0.02s ≦ 0.05s
DC ≦ 0.04s ≦ 0.065s
Max. operating frequency 1 cycle /s
Internal leakage JIS B8374 standard value
Installation position Free
Mass 2.1kg 3.8kg
●Use the valve with lubricator.
●Refer to catalog for details.

MVW2 5-Port Solenoid Valves

  • MVW2 5-Port Solenoid Valves
■MVW2(Return)
■Spool valve system, Pilot-acting type
■Direct piping type
■Port size:Rc1/4 , Rc3/8
Model code Return MVW2
Port size Rc1/4 , Rc3/8
Operating pressure 0.12~0.7MPa
Fluid temperature -20~60℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Ambient temperature -20~50℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Effective sectional area 15mm2
Rated voltage AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V,110V,200V,220V
Response time AC ≦ 0.02s
DC ≦ 0.026s
Max. operating frequency 1 cycle /s
Internal leakage JIS B8375:1993 standard value
Installation position Free
Mass 1.8kg
●Use the valve with lubricator.
●Refer to catalog for details.

MVS2 5-Port Solenoid Valves

  • MVS2 5-Port Solenoid Valves
■MVS2(Return)
■Spool valve system, Pilot-acting type
■Gasket-connected type
■Port size:Rc3/8 , Rc1/2 , Rc3/4 , Rc1
Model code Return MVS2
Port size Rc3/8 Rc1/2 Rc3/4 Rc 1
Operating pressure 0.12~0.7MPa
Fluid temperature -20~60℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Ambient temperature -20~50℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Effective sectional area 60mm2 70mm2 150mm2 165mm2
Rated voltage AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V,110V,200V,220V
Response time AC ≦ 0.05s ≦ 0.09s
DC ≦ 0.05s ≦ 0.09s
Max. operating frequency 1 cycle /s
Internal leakage JIS B8375:1993 standard value
Installation position It is desirable to mount the valve with the spool located horizontally.
Mass 2.5kg 5kg
●Use the valve with lubricator.
●Refer to catalog for details.

MVS120C,MVS150C 4-Port Solenoid Valves

  • MVS120C,MVS150C 4-Port Solenoid Valves
■MVS120C,MVS150C(Return)
■Spool valve system, Pilot-acting type
■Gasket-connected type
■Port size:Rc1 1/4 , Rc1 1/2
Model code Return MVS120C MVS150C
Port size Rc 1 1/4 Rc 1 1/2
Operating pressure 0.2~0.7MPa
Fluid temperature -20~60℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Ambient temperature -20~50℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Effective sectional area 250mm2 300mm2
Rated voltage AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V,110V,200V,220V
Response time ≦ 0.2s
Max. operating frequency 1 cycle /s
Internal leakage JIS B8375:1993 standard value
Installation position It is desirable to mount the valve with the spool located horizontally.
Mass 17kg 20kg
●Use the valve with lubricator.
●Refer to catalog for details.

MVD2 5-Port Solenoid Valves

  • MVD2 5-Port Solenoid Valves
■MVD2(Hold)
■Spool valve system, Pilot-acting type
■Gasket-connected type
■Port size:Rc3/8 , Rc1/2 , Rc3/4 , Rc1
Model code Hold MVD2
Port size Rc3/8 Rc1/2 Rc3/4 Rc 1
Operating pressure 0.12~0.7MPa
Fluid temperature -20~60℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Ambient temperature -20~50℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Effective sectional area 60mm2 70mm2 150mm2 165mm2
Rated voltage AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V,110V,200V,220V
Response time AC ≦ 0.03s ≦ 0.05s
DC ≦ 0.04s ≦ 0.065s
Max. operating frequency 1 cycle /s
Internal leakage JIS B8375:1993 standard value
Installation position It is desirable to mount the valve with the spool located horizontally.
Mass 3.5kg 5.9kg
●Use the valve with lubricator.
●Refer to catalog for details.

MVD120C,MVD150C 4-Port Solenoid Valves

  • MVD120C,MVD150C 4-Port Solenoid Valves
■MVD120C,MVD150C(Hold)
■Spool valve system, Pilot-acting type
■Gasket-connected type
■Port size:Rc1 1/4 , Rc1 1/2
Model code Hold MVD120C MVD150C
Port size Rc 1 1/4 Rc 1 1/2
Operating pressure 0.2~0.7MPa
Fluid temperature -20~60℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Ambient temperature -20~50℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Effective sectional area 250mm2 300mm2
Rated voltage AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V,110V,200V,220V
Response time ≦ 0.2s
Max. operating frequency 1 cycle /s
Internal leakage JIS B8375:1993 standard value
Installation position It is desirable to mount the valve with the spool located horizontally.
Mass 18kg 22kg
●Use the valve with lubricator.
●Refer to catalog for details.

MVPC1(2),MVPO1(2),MVPE1(2) 4-Port Solenoid Valves

  • MVPC1(2),MVPO1(2),MVPE1(2) 4-Port Solenoid Valves
■MVPC1,MVPC2(Closed center)MVPO1,MVPO2(Center open to exhaust)MVPE1,MVPE2(Center open to pressure)
■Spool valve system, Pilot-acting type
■Gasket-connected type
■Port size:Rc3/8 , Rc1/2 , Rc3/4 , Rc1 , Rc1 1/4 , Rc1 1/2
Model code Closed center MVPC1 MVPC2
Center open to exhaust MVPO1 MVPO2
Center open to pressure MVPE1 MVPE2
Port size Rc3/8 Rc1/2 Rc3/4 Rc 1 Rc 1 1/4 RC 1 1/2
Operating pressure 0.12~0.7MPa
Fluid temperature -20~60℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Ambient temperature -20~50℃(Remove moisture perfectly from the fluid to prevent freezing when used at 5℃ or lower.)
Effective sectional area 35mm2 60mm2 140mm2 180mm2 250mm2 350mm2
Rated voltage AC100V,110V,200V,220V(50/60Hz) DC24V,48V,100V,110V,200V,220V
Response time AC ≦ 0.3s ≦ 0.4s ≦ 0.5s
DC ≦ 0.4s ≦ 0.52s
Max. operating frequency 1 cycle /s
Internal leakage JIS B8375:1993 standard value
Installation position It is desirable to mount the valve with the spool located horizontally.
Mass 13.5kg 25.0kg 31.5kg
●Use the valve with lubricator.
●Refer to catalog for details.