Rodless Cable Cylinders  Pneumatic/Hydraulic

Rodless Cable Cylinders
■Space-saving type to meet factory requirements
 Cable cylinders are designed to reduce installation space and require only half the space needed for rod cylinders.
■Excellent versatility allowing functional design
 Stroke length can be set up to 18 m using tube coupler.
■Factory automation-oriented multiple functions
 Cable coated with special nylon is highly airtight and strong enough to resolve problems of friction and bending due to heavy rod.

CC series Double acting (standard) CC:Pneumatic CCV:Hydraulic

  • CC series Double acting (standard)
■Bore size:12.7mm(1/2")~101.6mm(4")
■Space needed for installation is only half that of rod cylinders.
 Problem of bending due to heavy rod can be solved.
Model code Pneumatic CC05 CC07 CC10 CC15 CC20 CC25 CC30 CC40 CC52
Hydraulic - CCV07 CCV10 CCV15 CCV20 CCV25 CCV30 CCV40 CCV52
Bore size (mm) 12.7 19.1 25.4 38.1 50.8 63.5 76.2 101.6 50.8
(inch) 1/2" 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 2"
Max.Working pressure 0.7MPa 1.4MPa 3.5MPa
Max. permissible
piston speed
Pneumatic 500mm/s 1000m/s 500m/s 1000mm/s
Hydraulic 200mm/s 200m/s 1000m/s 500m/s
Tube materials Steel - -
Aluminum
Tube surface Steel Lacquer paint
Aluminum Alumite finish
Cushion None Both ends(fixed orifice) Both ends(variable type)
Ambient temp -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.)
Option Automatic tensioner -
Reed switches
●Refer to catalog for details.

SA series  Single acting SA:Pneumatic SAV:Hydraulic

  • SA series  Single acting
■Bore size:19.1mm(3/4")~50.8mm(2")
■Pneumatic cylinder that returns by gravity. SA series are suitable for load lifting applications. The cylinder supplies pressure only at lifting up a load.
■Installation of the cylinder can be horizontal, perpendicular, or slope.
Model code Pneumatic SA07 SA10 SA15 SA20 SA25 SA30 SA40 SA52
Hydraulic SAV07 SAV10 SAV15 SAV20 SAV25 SAV30 SAV40 SAV52
Bore size (mm) 19.1 25.4 38.1 50.8 63.5 76.2 101.6 50.8
(inch) 3/4" 1" 1 1/2" 2" 2 1/2" 3" 4" 2"
Max.Working pressure 0.7MPa 1.4MPa 3.5MPa
Tube materials Steel -
Aluminum
Tube surface Steel Lacquer paint
Aluminum Alumite finish
Cushion Both ends(fixed orifice) Both ends(variable type)
Ambient temp. -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.)
Option Reed switches
●Refer to catalog for details.

DP series With double purchase kit DP:Pneumatic DPV:Hydraulic

  • DP series With double purchase kit
■Bore size:38.1mm(1 1/2")~50.8mm(2")
■Load can be traveled double the length of cylinder stroke.
■Ensures further space-saving compared to standard type.
Model code Pneumatic DP15 DP20 DP25 DP30 DP40 DP52
Hydraulic DPV15 DPV20 DPV25 DPV30 DPV40 DPV52
Bore size (mm) 38.1 50.8 63.5 76.2 101.6 50.8
(inch) 1 1/2" 2" 2 1/2" 3" 4" 2"
Max.Working pressure 0.7MPa 1.4MPa 3.5MPa
Tube materials Steel
Aluminum
Tube surface Steel Lacquer paint
Aluminum Alumite finish
Cushion Both ends(variable type)
Ambient temp. -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.)
Option Automatic tensioner
Reed switches
●Refer to catalog for details.

TC series With tracking rail TC:Pneumatic TCV:Hydraulic

  • TC series With tracking rail
■Bore size:12.7mm(1/2")~38.1mm(1 1/2")
■TC series cable cylinders with tracking rail have linear bearing at load mounting block.It runs on the quenched ground shaft.
 Without need for guide to support loads, it is easy to install.
Model code Pneumatic TC05 TC07 TC10 TC15
Hydraulic - TCV07 TCV10 TCV15
Bore size (mm) 12.7 19.1 25.4 38.1
(inch) 1/2" 3/4" 1" 1 1/2"
Max.Working pressure 0.7MPa
Tube materials Steel - -
Aluminum
Tube surface Steel Lacquer paint
Aluminum Alumite finish
Cushion None Both ends(fixed orifice) Both ends(variable type)
Ambient temp. -5~60℃(The air must be dried the ambient temperature may drop below 5℃ to prevent problems due to freezing.)
Option Automatic tensioner -
Reed switches
●Refer to catalog for details.

Option Automatic tesioner

  • Option Automatic tesioner
Automatic tensioner always gives certain degree of tension to the cable.
As good relationship between cable and ground seal are maintained, longer seal life is guaranteed.
No bending due to stretched cable occurs, minimizing wearing of cable.
●Refer to catalog for details.

Option Reed switches

  • Option Reed switches
As piston incorporating magnet comes closer to reed switch, contact is closed and switch turns ON.
Suitable for operation check, detection, and interlock as a controller of sequencer or computer.
Can be mounted on a cylinder with automatic tensioner and tracking rail.
Model code RT BT CT形(TRIAC)
Circuit Single pole,Single circuit Single pole,Double circuit Single pole,Single circuit
Applicable voltage MAX DC200V MAX DC175V AC100・110V(50/60Hz)
Max. Contact capacity MAX 10VA MAX 3VA -
Max. Operating current 0.5A(at 40℃) 0.25A(at 40℃) 1.0A(at 30℃)
Response time 1ms or less 1ms or less 1ms or less
Ambient temp -40~70℃ -40~60℃
Leakage current - - 1mA or less
Indicator LED - -
Wiring diagrams RT Wiring diagram BT Wiring diagram CT Wiring diagram
Leadwire length 5m 5m 5m
●Refer to catalog for details.