Solenoid Valves for Fluid Control MAGFLOW series

Solenoid Valves for Fluid Control MAGFLOW series
Konan’s solenoid valves for fluid control provide reliable interface between fluids and automation systems.
A wide variety of products based on safe design are available to meet your own application.

YS30 series Mini-type Direct-acting 2-port Solenoid Valve

  • YS30 series Mini-type Direct-acting 2-port Solenoid Valve
YS30 series 2-port solenoid valves are available in NC or NO type,with port sizes Rc1/8 to 3/8.
The compact design enables space-saving installation.

■Applicable fluid:Air / Gas / Water / Kerosene / Steam / Vacuum
■Valve type : YS301(Normally closed type) YS302(Normally open type)
■Operation type : Mini-type Direct-acting
■Port size:Rc1/8 , Rc1/4 , Rc3/8
Model code Normally closed YS301(Valve opens when solenoid is energized.)
Normally open YS302(Valve opens when solenoid is de-energized.)
Port size Rc1/8 , Rc1/4 , Rc3/8
Orifice size 1.2~9.5mm
Materials Body Brass, stainless steel
Seal / seat Nitrile rubber, fluorine rubber, PTFE, ethylene propylene rubber
Housing Standard Conduit type(NEMA1)
Others Explosion-proof enclosure (d2G4, Exd Ⅱ BT4), Drip-proof, housing with terminal box, and others.
Rated voltage AC100V,110V,200V,220V(50/60Hz),AC120V,240V(60Hz) DC24V,100V,120V,125V
Allowable voltage fluctuation –15% to 10% of applicable voltages
Insulation class Continuous rating class F and H
Leadwire length Min.450mm
Ambient
temperature
Max. 50℃ (Temperature may differ depending on coil and fluid temperature. Refer to catalog for details.)
Min. Min. –20℃ (Temperature may depending on seat materials. Refer to catalog for details.)
Installation position As desired
Options, others Mounting bracket, manual operating system, neon lamp, surge absorber, oil-free
●Refer to catalog for details.

YS21 series Pilot-acting 2-port Solenoid Valves

  • YS21 series Pilot-acting 2-port Solenoid Valves
YS21 series 2-port solenoid valves are pilot-acting diaphragm valves, available for NC or NO operation.
With wide range of port sizes from Rc3/8 to 2, the valves meet diverse applications.

■Applicable fluid:Air / Gas / Water / Kerosene
■Valve type : YS211(Normally closed type) YS212(Normally open type)
■Operation type : Pilot-acting
■Port size:Rc3/8 , Rc1/2 , Rc3/4 , Rc 1 , Rc 1 1/4 , Rc 1 1/2 , Rc 2
Model code Normally closed YS211 (Valve opens when solenoid is energized.)
Normally open YS212(Valve opens when solenoid is de-energized.)
Port size Rc3/8 , Rc1/2 , Rc3/4 , Rc 1 , Rc 1 1/4 , Rc 1 1/2 , Rc 2
Orifice size 15.9 , 19.1 , 25.0 , 32.0mm
Materials Body Brass, stainless steel, bronze
Seal / seat Nitrile rubber, fluorine rubber, ethylene propylene rubber
Housing Standard Conduit type(NEMA1)
Others Explosion-proof enclosure (d2G4, Exd Ⅱ BT4), Drip-proof, housing with terminal box, and others.
Rated voltage AC100V,110V,200V,220V(50/60Hz),AC120V,240V(60Hz) DC24V,100V,120V,125V
Allowable voltage fluctuation –15% to 10% of applicable voltages
Insulation class Continuous rating class F and H
Leadwire length Min.450mm
Ambient
temperature
Max. 50℃(Temperature may differ depending on coil and fluid temperature. Refer to catalog for details.)
Min. -17℃(Temperature may depending on seat materials. Refer to catalog for details.)
Installation position As desired
Options, others Mounting bracket, neon lamp, surge absorber, oil-free, Manual operating system
●Refer to catalog for details.

YS20 series Zero differential Pressure Pilot-acting 2-port Solenoid Valves

  • YS20 series Zero differential Pressure Pilot-acting 2-port Solenoid Valves
YS20 series 2-port solenoid valves are hanging diaphragm valve that start operation with zero differential pressure.
The valves are applicable for pressures from –100 kPa to 0.96 MPa.

■Applicable fluid:Air / Gas / Water / Kerosene / Vacuum
■Valve type : YS201(Normally closed type)YS202(Normally open type)
■Operation type : Zero differential Pressure Pilot-acting
■Port size:Rc3/8 , Rc1/2 , Rc3/4 , Rc 1 , Rc 1 1/4 , Rc 1 1/2 , Rc2
Model code Normally closed YS201 (Valve opens when solenoid is energized.)
Normally open YS202(Valve opens when solenoid is de-energized.)
Port size Rc3/8 , Rc1/2 , Rc3/4 , Rc 1 , Rc 1 1/4 , Rc 1 1/2 , Rc 2
Orifice size 15.9 , 19.1 , 25.0 , 32.0mm
Materials Body Brass, stainless steel
Seal / seat Nitrile rubber, fluorine rubber, ethylene propylene rubber
Housing Standard Conduit type(NEMA1)
Others Explosion-proof enclosure (d2G4, Exd Ⅱ BT4), Drip-proof, housing with terminal box, and others.
Rated voltage AC100V,110V,200V,220V(50/60Hz),AC120V,240V(60Hz) DC24V,100V,120V,125V
Allowable voltage fluctuation –15% to 10% of applicable voltages
Insulation class Continuous rating class F and H
Leadwire length Min.450mm
Ambient
temperature
Max. 50℃(Temperature may differ depending on coil and fluid temperature. Refer to catalog for details.)
Min. -17℃(Temperature may depending on seat materials. Refer to catalog for details.)
Installation position As desired
Options, others Mounting bracket, neon lamp, surge absorber, oil-free, Manual operating system
●In some cases the valve may not fully open / close with slight supply-pressure.
●Refer to catalog for details.

YS27 series Zero differential Pressure Pilot-acting 2-port Solenoid Valves

  • YS27 series Zero differential Pressure Pilot-acting 2-port Solenoid Valves
YS27 series 2-port solenoid valves are hanging diaphragm valve that start operation with zero differential pressure.
The valves are applicable for wide range of pressures, from –100 kPa to 0.86MPa.

■Applicable fluid:Air / Gas / Water / Kerosene / Vacuum
■Valve type : YS271(Normally closed type)YS272(Normally open type)
■Operation type : Zero differential Pressure Pilot-acting 
■Port size:Rc 1 , Rc 1 1/4 , Rc 1 1/2 , Rc 2
Model code Normally closed YS271 (Valve opens when solenoid is energized.)
Normally open YS272(Valve opens when solenoid is de-energized.)
Port size Rc 1 , Rc 1 1/4 , Rc 1 1/2 , Rc 2
Orifice size 25.0 , 32.0mm
Materials Body Brass, stainless steel, bronze
Seal / seat Nitrile rubber, fluorine rubber, ethylene propylene rubber
Housing Standard Conduit type(NEMA1)
Others Drip-proof, housing with terminal box, and others.
Rated voltage AC100V,110V,200V,220V(50/60Hz),AC120V,240V(60Hz) DC24V,100V,120V,125V
Allowable voltage fluctuation –15% to 10% of applicable voltages
Insulation class Continuous rating class H
Leadwire length Min.450mm
Ambient
temperature
Max. 50℃(Temperature may differ depending on coil and fluid temperature. Refer to catalog for details.)
Min. -17℃(Temperature may depending on seat materials. Refer to catalog for details.)
Installation position Place the valve with solenoid standing upright.
Options, others Neon lamp, surge absorber, oil-free
●In some cases the valve may not fully open / close with slight supply-pressure.
●Refer to catalog for details.

YS23series Pilot-acting 2-port Solenoid Valves

  • YS23series Pilot-acting 2-port Solenoid Valves
By original piston structure,realized high durability.

■Applicable fluid:Steam
■Valve type : YS231(Normally closed type)
■Operation type : Pilot-acting
■Port size:Rc3/8 , Rc1/2 , Rc3/4 , Rc 1 , Rc 1 1/4 , Rc 1 1/2
Model code Normally closed YS231 (Valve opens when solenoid is energized.)
Port size Rc3/8 , Rc1/2 , Rc3/4 , Rc 1 , Rc 1 1/4 , Rc 1 1/2
Orifice size 21.0 , 30.0 , 40.0mm
Materials Body Brass
Seal / seat PTFE
Housing Standard Conduit type(NEMA1)
Others NEMA4 drip-proof
Rated voltage AC100V,110V,200V,220V(50/60Hz),AC120V,240V(60Hz)
Allowable voltage fluctuation –10% to 10% of applicable voltages
Insulation class Continuous rating class H
Leadwire length Min.450mm
Ambient
temperature
Max. 60℃
Min. 5℃
Installation position Installation of the valve with its head up is recommended.
●Refer to catalog for details.

YS33series Mini-type Direct-acting 3-port Solenoid Valve

  • YS33series Mini-type Direct-acting 3-port Solenoid Valve
YS33 series mini-type 3-port solenoid valves are available in NC, NO, and universal types with port size Rc 1/8 or 1/4.
With the compact design, the valves are also suitable for use as pilot valves.

■Applicable fluid:Air / Gas / Water / Kerosene / Vacuum
■Valve type : YS333(Normally closed type)YS334(Normally open type)YS336(Universal type)
■Operation type : Mini-type Direct-acting
■Port size:Rc1/8 , Rc1/4
Model code Normally closed YS333 (Pressure is supplied to secondary port when solenoid is energized.)
Normally open YS334(Pressure is exhausted from secondary port when solenoid is energized.)
Universal type YS336( Valve can be used for NC or NO operation by switching pressure ports.)
Port size Rc1/8 , Rc1/4
Orifice size 1.6~4.4mm
Materials Body Brass, stainless steel
Seal / seat Nitrile rubber, fluorine rubber, ethylene propylene rubber
Poppet fork Polyacetal, stainless steel
Housing Standard Conduit type(NEMA1)
Others Explosion-proof enclosure (d2G4, Exd Ⅱ BT4), Drip-proof, housing with terminal box, and others.
Rated voltage AC100V,110V,200V,220V(50/60Hz),AC120V,240V(60Hz) DC24V,100V,120V,125V
Allowable voltage fluctuation –15% to 10% of applicable voltages
Insulation class Continuous rating class F and H
Leadwire length Min.450mm
Ambient
temperature
Max. 50℃(Temperature may differ depending on coil and fluid temperature. Refer to catalog for details.)
Min. -20℃(Temperature may depending on seat materials. Refer to catalog for details.)
Installation position As desired
Options, others Mounting bracket, manual operating system, neon lamp, surge absorber, oil-free
●Refer to catalog for details.

YS203/204series Pilot-acting 3-port Solenoid Valves

  • YS203/204series Pilot-acting 3-port Solenoid Valves
YS203/204 series pilot-operated diaphragm style 3-port solenoid valves show distinguished performance in high flow rate applications.
The valves have no sliding parts, thus free from damage by contaminated fluids.
The valves function with high reliability.

■Applicable fluid:Air / Gas
■Valve type : YS203(Normally closed type)YS204(Normally open type)
■Operation type : Pilot-acting
■Port size:Rc3/8 , Rc1/2
Model code Normally closed YS203(Pressure is supplied to secondary port when solenoid is energized.)
Normally open YS204(Pressure is exhausted from secondary port when solenoid is energized)
Port size Rc3/8 , Rc1/2
Orifice size 15.9mm
Materials Body Brass
Seal / seat Nitrile rubber, fluorine rubber, ethylene propylene rubber
Poppet fork Polyacetal, stainless steel
Housing Standard Conduit type(NEMA1)
Others Explosion-proof enclosure (d2G4, Exd Ⅱ BT4), Drip-proof, housing with terminal box, and others.
Rated voltage AC100V,110V,200V,220V(50/60Hz),AC120V,240V(60Hz) DC24V,100V,120V,125V
Allowable voltage fluctuation –15% to 10% of applicable voltages
Insulation class Continuous rating class F and H
Leadwire length Min.450mm
Ambient
temperature
Max. 50℃(Temperature may differ depending on coil and fluid temperature. Refer to catalog for details.)
Min. -17℃(Temperature may depending on seat materials. Refer to catalog for details.)
Installation position As desired
Options, others Mounting bracket, manual operating system, neon lamp, surge absorber, oil-free
●Refer to catalog for details.

YS32series Pilot-acting 3-port Solenoid Valves

  • YS32series Pilot-acting 3-port Solenoid Valves
YS32 series pilot-operated piston style 3-port solenoid valves show distinguished performance in high flow rate applications.
The valves have large orifice.
The valves have high reliability as quick exhaust valve.

■Applicable fluid:Air / Gas / Kerosene
■Valve type : YS321(Normally closed type)YS322(Normally open type)
■Operation type : Pilot-acting 
■Port size:Rc1/4 , Rc3/8
Model code Normally closed YS321(Pressure is supplied to secondary port when solenoid is energized.)
Normally open YS322(Pressure is exhausted from secondary port when solenoid is energized.)
Port size Rc1/4 , Rc3/8
Orifice size Pressure side:7.1mm Exhaust side:8.7mm
Materials Body Brass
Seal / seat Nitrile rubberr, fluorine rubber
Poppet fork Polyacetal, stainless steel
Housing Standard Conduit type(NEMA1)
Others Explosion-proof enclosure (d2G4, Exd Ⅱ BT4), Drip-proof, housing with terminal box, and others.
Rated voltage AC100V,110V,200V,220V(50/60Hz),AC120V,240V(60Hz) DC24V,100V,120V,125V
Allowable voltage fluctuation –15% to 10% of applicable voltages
Insulation class Continuous rating class F and H
Leadwire length Min.450mm
Ambient
temperature
Max. 50℃(Temperature may differ depending on coil and fluid temperature. Refer to catalog for details.)
Min. -17℃(Temperature may depending on seat materials. Refer to catalog for details.)
Installation position As desired
Options, others Manual operating system,neon lamp, surge absorber
●Refer to catalog for details.