Pneumatic Line components / Auxiliary Equipment for Instrumentation

Auxiliary Equipment for Instrumentation

Safety Block Valves

  • Safety Block Valves
This is a safety line component that installed between three-position directional control valves and cylinders.
It is used to ensure that the cylinder is held in the mid-position when stopped at the middle of its stroke.
It protects equipments against accidents that may result from the cylinder unexpectedly moving from its middle stopping position.

■CVD1:Standard type(Port size:Rc1/4 , Rc3/8 , Rc1/2 , Rc3/4 , Rc1)
Model code CVD1-03 CVD1-04 CVD1-08
Port size 8A 10A 10A 15A 20A 25A
Rc1/4 Rc3/8 Rc3/8 Rc1/2 Rc3/4 Rc1
Effective sectional area 30mm2 40mm2 70mm2 80mm2 200mm2 220mm2
Operating pressure 0.12~1.0MPa
Cracking pressure 0.05MPa
Proof pressure 1.5MPa
Frequency of operations 2 cycle/s Max.
Operating temperature -20~60℃(For use below 5℃ ,provide adequate measures against freezing.)
Mass 0.4kg 0.9kg 2.0kg
●In the event of use in high bry air over dew point -40℃ ,please contact us.
●Refer to catalog for details.

Lockup Valves

  • Lockup Valves
This valve responds to abnormal drops in the supply air pressure in the pneumatic line,ensuring that the set pressure for the driven unit is
maintained until the supply pressure returns to normal.
It also locks the actuator to prevent unexpected movements if the supply pressure varies.

■LVS5(One-circuit)/ LVD5(Two-circuit):General purpose(Port size:Rc1/4 , Rc3/8 , Rc1/2 , Rc3/4 , Rc1)
■LVS5-HT(One-circuit)/ LVD5-HT(Two-circuit) Heat-resistant(Port size:Rc1/4 , Rc3/8 , Rc1/2 , Rc3/4 , Rc1)
Mode code General purpose LVS5-02 LVS5-04 LVS5-08 LVD5-02
Heat-resistant LVS5-02-HT LVS5-04-HT LVS5-08-HT LVD5-02-HT
Number of circuits One-circuit Two-circuit
Port size 8A 10A 10A 15A 20A 25A 8A 10A
Rc1/4 Rc3/8 Rc3/8 Rc1/2 Rc3/4 Rc1 Rc1/4 Rc3/8
Effective sectional area 17mm2 22mm2 30mm2 49mm2 83mm2 137mm2 17mm2 22mm2
Operating pressure Signal pressure Max. 1.0MPa
Supply pressure Max. 0.7MPa
Pressure setting 0.14~0.7MPa
Pressure differential 0.01MPa or less
Proof pressure 1.5MPa
Operating temperature General purpose-20~60℃ Heat-r e sistant5~100℃
Mass 0.6kg 1.7kg 2.6kg 1.0kg
●For specifications other than those listed above,please contact us.
●In the event of use in high dry air above dew point -40℃ ,please contact us.
●Refer to catalog for details.

Slow-Start Valves

  • Slow-Start Valves
This valve prevents accidents that may arise from a cylinder suddenly rising in response to the operation of a solenoid valve, etc.
It has a builtin bleed mechanism to supply air to the cylinder gradually at the initial stage of operation of the cylinder, and by automatically
opening the main valve at high speed when the pressure in thecylinder rises enough.

■SSV2:Standard type(Port size:Rc3/8 , Rc1/2)
Model code SSV2-04
Port size 10A 15A
Rc3/8 Rc1/2
Operating pressure 0.1~1.0MPa
Proof pressure 1.5MPa
Operating temperature -20~60℃(For use below 5℃ ,provide adequate measures against freezing.)
Mass 1.4kg
●In the event of use in high bry air over dew point -40℃ ,please contact us.
●Refer to catalog for details.

Pressure Detection Valves

  • Pressure Detection Valves
This valve detects signal pressure(air pressure)and controls other valves to which it is attached;when mounted on a shutoff valve,
for example,it operates the shutoff valve if it detects a signal pressure drop.
■PSV5:3 Ports Standard type(Port size:Rc3/8 , Rc1/2)■PSV5S:3 Ports Corrosion-resistant type(Port size:Rc3/8 , Rc1/2)

5-port type pressure detection valve detects signal pressure(air pressure)and directly control other actuators.
■PSV2:5 Ports Standard type(Port size:Rc1/4 , Rc3/8)■PSV2S:5 Ports Corrosion-resistant type(Port size:Rc1/4 , Rc3/8)
■PSV3L:5 Ports Low pressure purpose(Port size:Rc1/4 , Rc3/8)
■PSV3LS:5 Ports Low pressure purpose・Corrosion-resistant type(Port size:Rc1/4 , Rc3/8) 
Number of ports 3 Ports 5 Ports 5 Ports(Low pressure purpose)
Model code Standard type
(Corrosion-resistant type)
PSV5-04
(PSV5S-04)
PSV2-02
(PSV2S-02)
PSV3L-02
(PSV3LS-02)
Port size 10A 15A 8A 10A 8A 10A
Rc3/8 Rc1/2 Rc1/4 Rc3/8 Rc1/4 Rc3/8
Effective sectional area 32mm2 48mm2 22mm2 22mm2
Operating pressure Signal pressure Max. 1.0MPa Max. 0.5MPa
Supply pressure Max. 0.7MPa Max. 0.7MPa
Pressure setting 0.06~0.7MPa 0.03~0.2MPa
Proof pressure 1.5MPa 1.05MPa
Operating temperature -5~60℃
Mass 1.5kg
●In the event of use in high bry air over dew point -40℃ ,please contact us.
●Refer to catalog for details.